Friday, 15 April 2011

Update to Finding Server's Network Port Programatically

As I posted yesterday I said I may update the batch file to do a little more, well I've been sat around awaiting an engineer so I made a start on doing some improvements.

The following scripts attempts to find the physical adapters in a server that are enabled and arent the HP Teaming Adapter (we are a HP house, so tough if  your not!! :)

Once it has found the adapters it builds the interface name dynamically using the GUID as this is supported by TCPDUMP and then listens for a CDP packet (This is a cisco function that could have been disabled by your network administrators)

After the packet has been recieved it does some pretty messy string manipulation, because I couldnt be bothered to pull my hair out with RegEx. After I have pulled out the information I want I check to see if the Adapter description has the switch port information and update the description if it doesn't.

The script can be ammended to not update the NIC description and just output the details to screen by commenting and uncommenting a few lines.

** Update 21-04-11 - Added code to swap to cscript rather than wscript. **

' ******************************************************************
' NameAdapters.vbs
' ******************************************************************
' Determine Pysical NIC Adapters for Team
' David Wallis - 15/04/11
' ******************************************************************

' ******************************************************************
' Check Script is being run with CSCRIPT rather than WSCRIPT due to using stdout
' ******************************************************************
    
If UCase(Right(Wscript.FullName, 11)) = "WSCRIPT.EXE" Then
    strPath = Wscript.ScriptFullName
 Wscript.Echo "This script must be run under CScript." & vbCrLf & vbCrLf & "Re-Starting Under CScript"
    strCommand = "%comspec% /K cscript //NOLOGO " & Chr(34) & strPath & chr(34)
    Set objShell = CreateObject("Wscript.Shell")
    objShell.Run(strCommand)
    Wscript.Quit
End If

strComputer = "."

Const NETWORK_CONNECTIONS = &H31&

Set objShell = CreateObject("Wscript.Shell")
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set objShellApp = CreateObject("Shell.Application")
Set objFolder = objShellApp.Namespace(NETWORK_CONNECTIONS)


' NetEnabled is -1 when Enabled and 0 When the NIC is disabled

Set oAdapters = objWMIService.ExecQuery _
   ("Select * from Win32_NetworkAdapter where (NetEnabled = -1)")


' Enumerate the results (list of NICS). "
For Each oAdapter In oAdapters
 If oAdapter.ProductName = "HP Network Teaming Virtual Miniport Driver" Then
  'Teamed Adapter
 Else
  'Physical Nic - Execute TCPDUMP
  strCommand = "tcpdump -nn -v -s 1500 -i \Device\" & oAdapter.GUID & " -c 1 ether[20:2] == 0x2000" 

  Wscript.echo "Executing TCP Dump for Adapter " & chr(34) & oAdapter.NetConnectionID & chr(34) & " GUID:" & oAdapter.GUID & VbCrLF
  Set objExec = objShell.Exec(strCommand) 
   
  count = 0

  Do Until objExec.Status
   count = count +1
   'Timeout to Deal with Non CDP Enabled Devices
   If count = 1200 then
    wscript.echo "TCPDUMP Execution Timeout Exceeded, Script Quiting"
    wscript.quit
   End If
       Wscript.Sleep 250
  Loop 
  
  ' Loop through the output of TCPDUMP stored in stdout and retrieve required fields
  ' Namely switch name, IP and Port

  While Not objExec.StdOut.AtEndOfStream
     strLine = objExec.StdOut.ReadLine
   If Instr(UCASE(strLine),"DEVICE-ID") > 0 Then strDeviceID = Mid(strLine,(Instr(strLine,chr(39))+1),(Len(StrLine) - (Instr(strLine,chr(39))+1)))
   If Instr(UCASE(strLine),"ADDRESS ") > 0 Then strDeviceIP = Right(strLine,(Len(strLine) - (Instrrev(strLine,")")+1)))
   If Instr(UCASE(strLine),"PORT-ID") > 0 Then strPort = Mid(strLine,(Instr(strLine,chr(39))+1),(Len(StrLine) - (Instr(strLine,chr(39))+1)))
  Wend


  
  ' Rename Nic to Contain Switch Name and Port
  ' NetConnectionID Is readonly on some versions of Windows.
  
  strName = oAdapter.NetConnectionID
  Set colItems = objFolder.Items
  
  For Each objItem in colItems

       If objItem.Name = strName Then

    'Build Description to Append to Port Name 
    ' Windows doesn't like the / Character, so Replace it with a -

    strDescription = " (" & strDeviceID & " " & strDeviceIP &  " " & Replace(strPort,"/","-") & ")"

    ' If the port doesn't contain the switchport details then add them.
    
    If Instr(objItem.Name,strDescription) = 0 then
     wscript.echo "Ammending Adapter Description." & vbCrLf
     objItem.Name = strName & strDescription
    Else
     wscript.echo "Skipping Adapter Description Ammendment."
    End If
       End If
  Next ' objItem

  'wscript.echo "Details for Adapter " & chr(34) & oAdapter.NetConnectionID & Chr(34)
  'wscript.echo "MAC Addr: " & oAdapter.MACAddress & " Switch: " & strDeviceID & " " & strDeviceIP & " Port: " & strPort & vbCrLf

 End If

Next 'oAdapter


1 comment:

  1. After a long time, I read a very beautiful and very important article that I enjoyed reading. I have found that this article has many important points, I sincerely thank the admin of this website for sharing it. Best network ports service provider.

    ReplyDelete